Application Code | II
|
Type Version | mk1
|
Lamp Type | TL5
|
Number of Lamps | 2
piece/unit
|
Automatic Restart | Yes
|
Input Voltage | 220 to 240
V
|
Input Frequency | 50 to 60
Hz
|
Operating Frequency (Nom) | 45
kHz
|
Crestfactor (Nom) | 1.7
|
Power Factor 100% Load (Nom) | 0.98
|
Preheat Time | 1.6
s
|
Mains Voltage Performance (AC) | 202-254V-8%-+6%
|
Mains Voltage Safety (AC) | 198-264V-10%-+10%
|
Earth Leakage Current (Max) | 0.5
mA
|
Inrush Current Width | 0.35
ms
|
Ballast Factor (Nom) | 1.14
|
Power Losses (Nom) | 6/7
W
|
Inrush Current Peak (Max) | 30
A
|
Efficiency at full load [%] | 90
%
|
Connector Type Input Terminals | WAGO 744 connector
|
Cable Capacity Output Wires Mutual (Max) | 200
pF
|
Connector Type Output Terminals | WAGO 744 connector
[ Suitable for manual wiring] |
Cable Length Hot Wiring | 0.75
m
|
Wire Striplength | 8.0-9.0
mm
|
Dual Fixture Master/Slave | Possible, lamp wires 2m max. length
[ Master/Slave operation possible] |
Input Terminal Cross Section | 0.50-1.50
mm²
|
Output Terminal Cross Section | 0.50-1.50
mm²
|
Cable Capacity Cold Output Wires - Earth (Max) | 200
pF
|
Cable Capacity Hot Output Wires - Earth (Max) | 200
pF
|
Rated Ballast-Lamp Power | 24/39 W
|
Rated Lamp Power on TL5 | 24/39
W
|
System Power on TL5 | 56/83
W
|
Lamp Power on TL5 | 50/76
W
|
Power Loss on TL5 | 6.0/7.0
W
|
T-Ambient (Max) | 50
°C
|
T-Ambient (Min) | -15
°C
|
T-Storage (Range) | -40 °C to 80 °C
|
T-Storage (Max) | 80
°C
|
T-Storage (Min) | -40
°C
|
T-Case Lifetime (Nom) | 75
°C
|
T-Case Maximum (Max) | 75
°C
|
Housing | L 280x30x21.5
|
Nominal Light Output After 60 Seconds | 100% of EBLF
|
Normal Operating Voltage (DC) | 220-240
V
|
Battery Voltage Guaranteed Operation | 176-275
V
|
Battery Voltage Guaranteed Ignition | 186-275
V
|
Emergency Ballast Lumen Factor (EBLF) (Nom) | 100
%
|
Nominal Light Output After 5 Seconds | 50% of EBLF
|
Energy Efficiency Index | A2 BAT
|
||||||||||
IP Classification | IP 20
[ Ingress Protection 20] |
||||||||||
EMI 9 kHz ... 30 MHz | EN55015
|
||||||||||
Vibration Standard | IEC68-2-6 F c
|
||||||||||
Bumps Standard | IEC 68-2-29 Eb (10G/16ms)
|
||||||||||
Approval Marks | F-Marking
|
CE marking
|
ENEC certificate
|
CCC certificate
|
C-Tick certificate
|
PSB certification
|
TISI marking
|
SIRIM approval
|
CB Certificate
|
CCC certificate
|
VDE-EMV certificate
|
Hum And Noise Level | < 30 dB(A)
|
Ambient temperature range | -15 °C to 50 °C
|
Full product code | 872790093935400
|
Order product name | HF-S 2 24-39 TL5 II 220-240V 50/60Hz
|
EAN/UPC - Product | 8727900939354
|
Order code | 913713034566
|
Numerator - Quantity Per Pack | 1
|
Numerator - Packs per outer box | 12
|
Material Nr. (12NC) | 913713034566
|
Net Weight (Piece) | 0.210
kg
|