HF-Performer III for TL-D lamps

HF-P 118/136 TL-D III 220-240V 50/60 Hz

HF-P 118/136 TL-D III 220-240V 50/60 Hz

  • Unsurpassed energy-efficient and long-lasting solution

    Product information

Videos

[trigger to render Video Gallery]

Images

Specifications Show all

General Information
Application Code
III
Type Version
IDC
Lamp Type
TL-D
Number Of Lamps
1 piece/unit
Number Of Products On MCB (16A Type B) (Nom)
28
Automatic Restart
Yes
Operating and Electrical
Input Voltage
220 to 240 V
Input Frequency
50 to 60 Hz
Operating Frequency (Nom)
45 kHz
Ignition Method
Programmed Start
Crestfactor (Max)
1.7
Power Factor 100% Load (Nom)
0.98
Ignition Time (Max)
0.9 s
Mains Voltage Performance (AC)
-8%-+6%
Mains Voltage Safety (AC)
-10%-+10%
Earth Leakage Current (Nom)
0.5 mA
Inrush Current Width
0.25 ms
Constant Wattage Deviation
-2%/+2%
Ballast Factor (Nom)
1
Power Losses (Nom)
3.5 W
Inrush Current Peak (Max)
18 A
Wiring
Connector Type Input Terminals
WAGO 251 universal connector  [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Cable Capacity Output Wires Mutual (Nom)
200 pF
Connector Type Output Terminals
WAGO 251 universal connector  [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Cable Length Hot Wiring
0.75 m
Wire Striplength
8.0-9.0 mm
Dual Fixture Master/Slave
Not applicable  [ Master/Slave oper. not applicable]
Input Terminal Cross Section
0.50-1.00 mm²
Output Terminal Cross Section
0.50-1.00 mm²
Cable Capacity Output Wires To Earth (Nom)
200 pF
System characteristics
Rated Ballast-Lamp Power
36/18 W
Rated Lamp Power On TL-D
36/18 W
System Power On TL-D
35.2/19.1 W
Lamp Power On TL-D
31.1/16.6 W
Power Loss On TL-D
4.1/2.5 W
Rated Lamp Power On PL-L
36 W
System Power On PL-L
34.6 W
Lamp Power On PL-L
30.7 W
Power Loss On PL-L
3.9 W
Temperature
T-Ambient (Max)
60 °C
T-Ambient (Min)
-25 °C
T-Storage (Max)
50 °C
T-Storage (Min)
-40 °C
T-Case Lifetime (Nom)
80 °C
T-Case Maximum (Max)
80 °C
T-Ignition (Max)
60 °C
T-Ignition (Min)
-25 °C
Mechanical and Housing
Housing
L 280x30x28
Emergency Operation
Nominal Light Output After 60 Seconds
100% of EBLF
Battery Voltage Lamp Ignition
186-275 V
Normal Operating Voltage (DC)
220-240 V
Battery Voltage Lamp Operation
186-275
Battery Voltage Guaranteed Operation
176-275 V
Battery Voltage Guaranteed Ignition
186-275 V
Emergency Ballast Lumen Factor (EBLF) (Nom)
0.7 %
Nominal Light Output After 5 Seconds
50% of EBLF
Approval and Application
Energy Efficiency Index
A2 BAT
EMI 9 kHz ... 30 MHz
EN55015
EMI 30 MHz ... 1000 MHz
EN55022 level B
Safety Standard
IEC 61347-2-3
Performance Standard
IEC 60929
Quality Standard
ISO 9000:2000
Environmental Standard
ISO 14001
Harmonic Current Emission Standard
IEC 61000-3-2
EMC Immunity Standard
IEC 61547
Vibration Standard
IEC68-2-6 F c
Bumps Standard
IEC 68-2-29 Eb
Humidity Standard
EN 61347-2-3 clause 11
Approval Marks
CE marking
ENEC certificate
VDE-EMV certificate
Temperature Marking
Yes
Emergency Standard
IEC 60598-2-22
Hum And Noise Level
< 30 dB(A)
Product Data
Full product code
872790091164000
Order product name
HF-P 118/136 TL-D III 220-240V 50/60 Hz
EAN/UPC - Product
8711500999641
Order code
913713031566
Numerator - Quantity Per Pack
1
Numerator - Packs per outer box
12
Material Nr. (12NC)
913713031566
Net Weight (Piece)
0.202 kg
Installation Diagrams
Performance Diagrams

Recently Viewed

    • Manage your projects with MyProjects
      Use MyProjects to create, save manage and share items and projects with you colleagues and team members.
You are now visiting our Global professional lighting website, visit your local website by going to the USA website